Help Batch Purge and Remove Proxy

Batch Purge and Remove Proxy

BATCHPURGE

Purges unused layers, blocks, styles and registered applications, strips proxy objects left by a vertical product you no longer have installed, and removes ACIS objects that carry no geometry.

Use it when drawings have grown for no visible reason, a set opens with proxy-object warnings on a machine without Civil 3D or Plant 3D, or a drawing refuses to be saved to an older DWG or DXF format.

Step by step

  1. Add Files.

  2. Leave Keep a backup of each drawing ticked unless you have your own backup. Purging rewrites files in place, outside AutoCAD's UNDO.

  3. Choose what to clean.

  4. Press START BATCH PURGE and read the per-file counts in the log.

The options that change the result

OptionWhat it does
Deep Purge Unused ItemsRepeats a purge until nothing more can go, which reaches nested blocks that a single PURGE leaves behind.
Remove Proxy ObjectsRemoves orphaned proxy graphics — what a vertical product leaves behind when its software is not installed.
Remove empty ACIS objectsRemoves solids and bodies that have no geometry: the empty shells an exploded AEC object leaves behind. They draw nothing and select as nothing, but while they are in a drawing it cannot be saved or exported to any DWG or DXF older than 2013 — not by this tool and not by AutoCAD's own SAVEAS. Only objects AutoCAD cannot put a bounding box round are removed.
Bind Xref FilesConverts external references into blocks. Insert flattens the layer names rather than prefixing them with the xref name.
Detach unresolved XrefsRemoves references whose file can no longer be found, including images and PDFs.
Keep a backup of each drawingWrites the previous contents next to each file as <name>.cbp.bak.

Careful

“Also strip Civil 3D / Plant 3D / Advance Steel dictionaries” is destructive, and is off for a reason. On a drawing whose vertical product is still installed it deletes live object data — not orphaned graphics — and there is no way back, because the work happens in a side database that AutoCAD's UNDO cannot reach. Switching it on asks you to confirm. Use it only on drawings received from elsewhere that you will never open in the vertical.

Tip

Cannot save to DXF 2000, 2004, 2007 or 2010? Run this tool over the drawings first with Remove empty ACIS objects ticked. Empty ACIS shells are the usual thing standing in the way, and once they are gone the older formats work everywhere, AutoCAD's own SAVEAS included.

Watch the walkthrough on YouTube

Recorded before version 1.1.0. The ribbon and the icons in the video are the previous ones, and features added since — combining sheets into one PDF, regular expressions in Find and Replace, mirroring folder structure, removing empty ACIS objects — do not appear in it. What the tool does is unchanged; where the buttons sit is not.